Sharing is caring!

By Lacey Yates

If you read my August 2024 post, “Why You Need a Lab On Your Farm” and it inspired some of you to invest, or start saving, for an on-farm lab, then this post is really going to benefit you!  In the previous August post, I shared everything you needed to know, including a supply list with easy access links, to set up an on-farm lab. Now that we have the lab, what’s next?  How are you supposed to utilize this to benefit your farm?  What do you need to be working towards in terms of Coliform Counts and Aerobic Bacteria Counts?  What if you tested your milk and you have very high, or higher than the “raw milk industry standard” counts?  Let’s dive in and really discuss how to make your on-farm lab work FOR you, and help you produce the cleanest, yummiest, GOLD STANDARD raw milk that you possibly can. 

When you first get all your lab items, I suggest you find a permanent, clean place for your incubator.  I set my lab up on its designated table in the same room that my cheese cave is in.  On this table is also where I store all other “lab” items: binder with easy access testing procedures and also where I keep track and document all testing data, gloves, pipettes…It’s out of the way, out of sight, and easily accessible.  I also store my coliform and Aerobic plates, buffered water, and Accumast trays in my cheese cave fridge that sits next to my lab table. Since this fridge is really big, I have the bottom pull out trays dedicated to my lab items.  I will note here that I vacuum seal all cheeses, so there is no worry about contaminating my lab items.

Now that your lab is set up in a clean, out-of-the-way area, it’s time to run your tests.  Each test is slightly different in the procedure. (At the very end of this post is a handy print out for you to store in your lab binder.  It will walk you through step by step on how to perform each test, read each test, and also includes what counts to aim for all wrapped up in a quick reference guide!)  These first tests will be eye opening for you, especially if you are machine milking.  They will tell you how clean your practices are, and give you a very good indicator on if you need to work on things.  Do not be discouraged if you have high counts at first.  Just dive in and start troubleshooting!

When sampling milk for these specific tests, it is recommended you sample from the jar you will be drinking out of, making cheese from, or selling.  This milk has been filtered, bottled, and chilled.  The milk sampled is in its final phase, ready to consume.  You do not want to sample milk for coliform or aerobic testing in a sterile vial directly from the animal, as these results wouldn’t tell you anything you need to know.  This is how these tests differ from mastitis (Accumast) tests.  We’ll get into that on a separate post. 

What even are coliform and aerobic bacteria, and what standards should you be aiming for?  

Coliforms are a group of gram-negative bacteria that can ferment on lactose to produce acid and gas.  They are commonly found in soil, feces, and vegetation.  They can be reduced by managing manure, bedding, loading areas, and pastures properly, keeping mammary systems clean and dry, and by keeping milking equipment properly cleaned and sanitized.  Although coliforms can cause serious illness and/or contaminated cheese makes, the presence of coliforms in milk doesn’t necessarily mean that disease-causing bacteria are present.  The goal is to REDUCE risk by having low counts.  RAWMI Common Standards for Coliform count target is to have a three-month average of less than 10 per ml of raw milk.  The SPC measures the total number of aerobic bacteria in milk.  High numbers can indicate poor milk chilling, poorly cleaned equipment, or poor udder prep before milking.  RAWMI Common Standards for Aerobic (standard plate count, or SPC) target is to have a three-month average of less than 5,000 per ml of raw milk.  

While running the tests are very easy and take mere minutes to perform, they do require a longer incubation time of 18-24 hours depending on which test you’re performing.  Reading the tests are simple!  Coliform counts (blue plate below marked Goat): you count each dot you see.  The below goat coliform count is “7”.  While this is below the standard, I still personally like these counts lower.  Aerobic/SPC counts (pink plate below marked Goat) have an extra step in that you have to do a little multiplication.  Count each dot you see, which is 43 on the below goat Aerobic plate.  Since I added 1 mL of sampled milk to 9mL of buffered water (10mL total, and 1mL taken back out of the buffered water and milk mix to be dispensed onto plate an incubated, since it’s 10mL total, that’s the first part of our equation), then the counts are 10×43=430 aerobic bacteria.  430 is pretty great, especially since I do not have a bulk tank chiller, but use the sink/ice bath method for chilling bottled milk.  Remember, the procedure guide for each test is at the end of this post for you to print out and follow easily!

These above results are examples of my past personal tests I ran.  

The “Goat” samples were towards the end of the week PRIOR to breaking down my goat machine claw to clean.  The “Cow” tests are very good, and had just cleaned the claw the day before.  Keep in mind these are MACHINE results.  As stated in previous posts, machines are a different beast completely and attention to cleaning practices are a must (I’ve ran comparison tests between machine and hand milking, with hand milking coliform counts being 0-1, aerobic being around the 300 range.  I did this the first time after my very first test ran after machine milking when my counts were higher then I had anticipated… hand milking test results showed me the problem was within my MACHINE and to start trouble shooting there, versus needing to bother troubleshooting with udder prep!)   I like to test a couple times a week as I am looking for “trends” and  have learned the most about my cleaning practices in frequent testing.  While my Aerobic counts are always about the same and stay well within a good range, the Coliform Counts are what I like to pay attention to the most right now.  I have come to the conclusion that if I break my cow claw completely down once a week, the same time every week, my tests easily stay below industry standards.  My goat claws are a very different set up and I can go a couple months before having to break them down for a deep clean!  You can see the goat coliform counts are creeping up in number, indicating its time to deep clean all the cracks and crevices of the goat claw.  I also run a test 1-2 days post cleaning and counts are always much lower!  

These above tests were run by a friend of mine of raw milk she purchased off a store shelf (legally per those specific state laws, producer is to remain anonymous).  This friend of mine also has her own on-farm lab (we live several hours apart and can’t utilize the same lab), and runs her own micro dairy.  The results of the above tests were quite a shock.  We do know that the “anonymous” producer uses a machine, has a pipeline, and the pipeline feeds directly into a bulk chiller tank.  She does not have an on-farm lab, and had no idea that her milk severely exceeds raw milk common standards.  Cheese made from this milk would very likely be a waste due to contamination issues.  These are examples of really bad raw milk counts. 

So now you have tested your milk.  If you’re below “standards”, great!  Keep going, keep testing to ensure your practices are on par.  If you’re above standards, that’s ok!  Time to troubleshoot.  The first place to look  for troubleshooting both high counts is your milking equipment.  Cleaning with hot enough water and soap, utilizing acid to break down milk stone, and proper sanitizing are all important.  Replacing milk hoses and inflations regularly helps, too.  Reducing SPC (Aerobic) counts can be as simple as adjusting your udder prep before milking, or chilling your milk quickly utilizing the ice bath method.  

Here’s a link to RAWMI video training series.  You can scroll through them to watch at your own discretion, but they have some AMAZING information and ideas on how to troubleshoot and boost your current practices to help you produce clean raw milk.  


While my intention is to not scare you out of producing raw milk, it is merely important to understand that producing clean raw milk is important and should always be strived for.  It’s absolutely heartbreaking to spend hours making beautiful cheeses to open them months later after aging to find they’re contaminated and must be trashed.  A little work and knowledge early on can set you up for absolute cheesemaking success.  If you’re lucky enough to be in a state that allows the sale of your raw milk, and you’re selling it, you ABSOLUTELY need to be testing your milk on a regular basis.  This not only gives you and your customers piece of mind, but you KNOW you’re producing low risk, CLEAN milk.  

*Below are the testing procedures to print.  Put them in a binder, and make sure you log your testing results so you can see your own specific trends.  

Raising Arrows Lab Testing Procedures

Prep Steps

Step 1 – Be sure surface is clean

Step 2 – Verify incubator is 32-34*C / 90*F

Step 3 – Put on gloves 

Step 4 – Get out and place on work surface

Coliform Test

Step 1: Open pipettes and do not touch tip

Step 2: Use pipette to draw 1ml of raw milk from jar

Step 3: Lift plastic of peel plate with one hand and dispense the 1ml of milk into the middle with the other hand.  Do not touch tip to plate. Seal, place in incubator.

Step 4: Incubate 18-24 hrs at 33*C

Reading Coliform Test

Step 1 – Read once incubated for 18-24 hrs 

Step 2 – Count each dot that has appeared.  Do not multiply as there was no dilution of sample.  If you count 3 colonies (dots), your coliform count is simply 3 CC per ml.

Note:  0-2 cc/ml is excellent, 3-5 is ok, 6-8 not great.  10 colonies are allowed by the FDA of pasteurized products.  Properly produced raw milk should be much lower than 10! 

AC Test

Step 1 – Open 2nd pipette and do not touch tip

Step 2 – Use pipette to draw 1ml of raw milk and discharge it into the buffered water bottle. 

Step 3 – Without laying pipette down, close lid and gently invert water bottle several times all with the other hand.

Step 4 – Draw 1ml of water/milk solution into pipette and discharge onto AC peel plate. Seal, place in incubatorStep 5 – Incubate 24 hrs at 33*C

Reading AC Test

Step 1 – Read after 24 hrs of incubation

Step 2 – Count every visible dot

Step 3 – Multiply the total colony by 10 (by 10 because you diluted the 1ml sample by 9mls of water so it’s a 1/10 dilution.)

Note: 1000 is excellent, 5,000 is good, 10,00 is ok, 15,000 is not great, 20,000 is the amount of Aerobic bacteria allowed nationwide by the FDA in pasteurized milk products in store shelves.  Properly produced milk should be much lower than 20,000 APC/ml.

Sharing is caring!

One Response

Leave a Reply

Your email address will not be published. Required fields are marked *